212 860 9000 Get Free Estimate

EN-430 Electric Strike

Locksmith In New York

EN-430 Premium Electric Strike
For use in new or replacement installation in metal jambs. Designed to be used with mortise locks with up to 1″ throw* without the need of relocating the centerline

FEATURES


  • FACE PLATE – 1-1/4” X 4-7/8”
  • ALL STAINLESS STEEL CONSTRUCTION
  • DURABILITY – 1,000,000 Life cycles
  • HOLDING FORCE – 2000 lbs. UL tested
  • CAVITY DEPTH – 7/8”, CAVITY HEIGHT – 1-1/2”, CAVITY WIDTH – 1″
  • CAVITY CENTERLINE OFFSET 1″
  • HANDED-SPECIFY LH OR RH
  • MORTISE TYPE – Backset 1 3/4″ deep

STANDARDS


  • UL LISTED – 10B fire rated (Class A, 3-hour, Single Swing Doors)
  • UL LISTED – 1034 Burglary Resistant Locking Mechanism for Indoor or Outdoor Use
  • ANSI – 1-1/4” X 4-7/8” Fits Cutout Specification A115.1 (with Slight Jamb Modification)
  • BHMA – A156.5 – 1992, Grade 1

OPTIONAL FEATURES


  • NEW EN-LB: OPTICAL IR LATCHBOLT SENSOR AVAILABLE
  • EN-CA: Additional coil assemblies available in all voltages listed.
  • LOW VOLTAGE BUZZER for audible signal when using DC voltage. Specify BZ-12 for 12 VDC or BZ-24 for 24 VDC.

FINISH (Specify When Ordering)


  • STANDARD FINISH – Satin Stainless Steel US32D
  • SATIN BRASS – US4
  • BRIGHT BRASS – US3
  • DARK BRONZE – Powder Coated
  • BRIGHT CHROME – US26

    ELECTRICAL CHARACTERISTIC CHART**


FOUR MAGNETIC COILS AVAILABLE Color coded wires depict the voltage of each coil


 

VOLTAGE


12 VAC
24 VAC
12 VDC
24 VDC

WIRE COLOR


Blue(1), Orange/White(1)
Blue(1), Black/White(1)
Orange/White(2)
Black/White(2)

FAIL SECURE – NORMALLY LOCKED (Unlocked when energized) Units with AC coils are for Fail Secure (Intermittent duty) use only and should be energized for periods of less than one minute


VOLTAGE CURRENT /
AMPS
OHMS SOUND DUTY

 

12 VAC .70 4.5 Buzz Intm
24 VAC .37 18.0 Buzz Intm
12 VDC .28 43.0 Silent Intm/Cont
24 VDC .15 164.0 Silent Intm/Cont

 

FAIL SAFE (Reverse Action) NORMALLY UNLOCKED (EN430RS) (Locked When Energized) Continuous duty, either Fail Secure or Fail Safe action, need to use DC coil assemblies. Strikes energized for periods longer than one minute are to be considered continuous duty operation. Fail Safe: DC units can be ordered Fail Safe action by adding “RS” to model number. Fail Secure DC units can be changed to Fail Safe action by ordering optional part # EN-SLR-RS.


VOLTAGE CURRENT/AMPS OHMS SOUND DUTY

 

12 VDC .28 43.0 Silent Intm/Cont
24 VDC .15 164.0 Silent Intm/Cont

 

*1” throw based on 1/8” door gap.
**Specify voltage when ordering

 

COMPATIBLE LOCKSETS


 

ACCURATE 8500 SERIES
NT MONARCH 18-M, xx-m, 17-M
SARGENT 7700-8100
SCHLAGE L SERIES (L9010-L9082)
YALE 8700